Step | | Procedure & Parts & Tools |
1 |
|
REMOVE THE 6 SCREWS FROM THE BACK PANEL.
Torx T30 |
|
|
2 |
|
REMOVE THE BACK PANEL
|
3 |
|
REMOVE THE VAC MOTOR GASKET. SET THE VAC MOTOR ON THE FLOOR AS IT WILL FALL OUT OF MACHINE.
|
4 |
|
LOCATE THE CONNECTOR. TURN THE KEY ON AND TURN ON THE VAC MOTOR ON THE CONTROL PANEL.
|
5 |
|
INSERT LEADS INTO THE CONNECTOR. THE VOLT METER SHOULD READ 24 VOLTS. IF SO, THE VAC MOTOR IS GOOD.
Volt meter (True RMS capable) |
|
|